Fixed Air Quality Station (AQ-200)

Fixed Air Quality Station (AQ-200)   download


Air Quality stations deliver precise measurement data in real-time for a wide range of air pollutants in a discreet and compact package. Measurable parameters include: ozone (O3); nitrogen dioxide (NO2); nitrogen oxides (NOx): carbon monoxide (CO); carbon dioxide (CO2); sulphur dioxide (SO2); volatile organic compounds (VOC); and particulate matter by mass (PM10 and PM2.5) or size distribution (0.3 to 10 µm, 8-channels)

  • Multiple gas measurements
  • Real-time data acquisition
  • Multipoint factory calibration
  • Zero and Span calibration user facility
  • PC software included
  • Temperature and humidity sensors
  • Remote site operation
  • Particle monitoring PM2.5 PM10, TSP*
  • Pole or wall installation
  • Wind speed and direction sensors*
  • Compact and low weight

AQ-200 affords high performance within a flexible and cost-effective package. Sensors can be integrated that measure temperature, humidity, wind speed, wind direction, environmental noise, solar radiation and other meteorological parameters. Data is stored on an SD card and remotely accessible in real-time via GSM modem, low power radio, Ethernet or other communications.

The AQ-200 Air Quality Station meets the global trend towards the real-time measurement of air quality in the micro-environment. This is driven by the need to answer important questions in localized areas of human habitation using newer, smaller, lower cost, intelligent measurement technology linked by inexpensive network communication systems.

Detectable gases / parameters PM2.5 and PM10
Electronics / processor Micro controller
Power supply 230 V AC
Alarm Adjustable LOW and HIGH
Output Relays, 4 - 20 mA analog, RS 485, MODBUS
Technology EC & IR for gases, LASER for PM
Resolution 0.01 µg/m³
Accuracy ± 2 %
Operating temperature 0 - 55 °C
Sampling Direct plug-in
Housing Sheet steel (Standard Enclosure : MS Power coated Aluminium)
Weight 40 - 100 Kgs (Subject to configuration)

The above Parameter and Ranges are only indicative. Endee will build up and supply the analyser with Parameters, range and features to any Practical Configuration.

Note : Specifications and Features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. Due to endee's commitment to research, design and product improvement, specifications are subject to change without notice